AC drives & controls
  • Wish Lists
  • Sign in
  • Cart
AC drives & controls
  • Drives Back
    • Back Drives
    • All Drives
    • Decentral Drives Back
      • Back Decentral Drives
      • All Decentral Drives
      • Accessories for Decentral Drives
      • VACON® 100 X
      • VLT® Decentral Drive FCD 302
      • VLT® DriveMotor FCP 106
    • DrivePro® Services Back
      • Back DrivePro® Services
      • All DrivePro® Services
      • Exchange Units
      • Spare Parts
    • Enclosed Drives Back
      • Back Enclosed Drives
      • All Enclosed Drives
      • Accessories for Enclosed Drives
      • VACON® 100 FLOW Enclosed Drive
      • VACON® 100 INDUSTRIAL Enclosed Drive
    • Filters and Braking Options Back
      • Back Filters and Braking Options
      • All Filters and Braking Options
      • Comsys Active Filter
      • Danfoss Advanced Active Filter AAF 007
      • iC7 Filters and Braking Options
      • VACON® Filters and Braking Options
      • VLT® Filters and Braking Options
    • Gear Motors Back
      • Back Gear Motors
      • All Gear Motors
      • Accessories for Gear Motors
      • VLT® OneGearDrive®
    • Low Voltage Drives Back
      • Back Low Voltage Drives
      • All Low Voltage Drives
      • Accessories for Low Voltage Drives
      • iC2-Micro
      • iC7-Automation
      • VACON® 100 FLOW
      • VACON® 100 INDUSTRIAL
      • VACON® 20
      • VACON® NXP Air Cooled
      • VLT® AQUA Drive FC 202
      • VLT® AutomationDrive FC 300
      • VLT® HVAC Basic Drive FC 101
      • VLT® HVAC Drive FC 102
      • VLT® Midi Drive FC 280
      • VLT® Refrigeration Drive FC 103
    • Modules Back
      • Back Modules
      • All Modules
      • Accessories for Modules
      • iC7 System Modules
      • VACON® Modules
    • Motion Controls and Servo Drives Back
      • Back Motion Controls and Servo Drives
      • All Motion Controls and Servo Drives
      • VLT® Integrated Servo Drive ISD 510
    • Soft Starters Back
      • Back Soft Starters
      • All Soft Starters
      • Accessories for Soft Starter
      • VLT® Soft Starter MCD 600
  • Rosemount Back
    • Back Rosemount
    • All Rosemount
    • Measurement Instrumentation
  • ...
  • Wish Lists
  • Store Locator
  • Contact us:
  • USD
    • Back USD
    • Euro
    • US Dollar
    • British Pound
Help
  • USD
    • Euro
    • US Dollar
    • British Pound
Cart
Toggle menu
×
AC drives & controls
Do you have an inquiry? Send Enquiry
×

  1. Home
  2. Categories
  • Quick view
    Frequency Converter FC-102P11KT2E21H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P11K) 11 KW / 15 HP,  Three phase, 200 - 240 VAC,IP21 / Type 1 RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: B1 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P11KT2E21H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P11KT2E21H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P11K) 11 KW / 15 HP, Three phase, 200 - 240 VAC,IP21 / Type 1RFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Disconnect + …

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P7K5T2E21H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P7K5) 7.5 KW / 10 HP,  Three phase, 200 - 240 VAC,IP21 / Type 1 RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: B1 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P7K5T2E21H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P7K5T2E21H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P7K5) 7.5 KW / 10 HP, Three phase, 200 - 240 VAC,IP21 / Type 1RFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Disconnect +…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P5K5T2E21H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P5K5) 5.5 KW / 7.5 HP,  Three phase, 200 - 240 VAC,IP21 / Type 1 RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: B1 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P5K5T2E21H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P5K5T2E21H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P5K5) 5.5 KW / 7.5 HP, Three phase, 200 - 240 VAC,IP21 / Type 1RFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Disconnect …

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P45KT2P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P45K) 45 KW / 60 HP,  Three phase, 200 - 240 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: C2 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P45KT2P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P45KT2P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P45K) 45 KW / 60 HP, Three phase, 200 - 240 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Dis…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P37KT2P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P37K) 37 KW / 50 HP,  Three phase, 200 - 240 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: C2 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P37KT2P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P37KT2P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P37K) 37 KW / 50 HP, Three phase, 200 - 240 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Dis…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P30KT2P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P30K) 30 KW / 40 HP,  Three phase, 200 - 240 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: C1 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P30KT2P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P30KT2P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P30K) 30 KW / 40 HP, Three phase, 200 - 240 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Dis…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P22KT2P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P22K) 22 KW / 30 HP,  Three phase, 200 - 240 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: C1 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P22KT2P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P22KT2P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P22K) 22 KW / 30 HP, Three phase, 200 - 240 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Dis…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P18KT2P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P18K) 18.5 KW / 25 HP,  Three phase, 200 - 240 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: C1 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P18KT2P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P18KT2P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P18K) 18.5 KW / 25 HP, Three phase, 200 - 240 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains D…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P15KT2P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P15K) 15 KW / 20 HP,  Three phase, 200 - 240 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: B2 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P15KT2P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P15KT2P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P15K) 15 KW / 20 HP, Three phase, 200 - 240 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Dis…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P11KT2P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P11K) 11 KW / 15 HP,  Three phase, 200 - 240 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: B1 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P11KT2P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P11KT2P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P11K) 11 KW / 15 HP, Three phase, 200 - 240 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Dis…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P7K5T2P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P7K5) 7.5 KW / 10 HP,  Three phase, 200 - 240 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: B1 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P7K5T2P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P7K5T2P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P7K5) 7.5 KW / 10 HP, Three phase, 200 - 240 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Di…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P5K5T2P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P5K5) 5.5 KW / 7.5 HP,  Three phase, 200 - 240 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: B1 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P5K5T2P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P5K5T2P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P5K5) 5.5 KW / 7.5 HP, Three phase, 200 - 240 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains D…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P3K7T2P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P3K7) 3.7 KW / 5.0 HP,  Three phase, 200 - 240 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: A5 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P3K7T2P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P3K7T2P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P3K7) 3.7 KW / 5.0 HP, Three phase, 200 - 240 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains D…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P2K2T2P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P2K2) 2.2 KW / 3.0 HP,  Three phase, 200 - 240 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: A5 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P2K2T2P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P2K2T2P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P2K2) 2.2 KW / 3.0 HP, Three phase, 200 - 240 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains D…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P37KT4P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P37K) 37 KW / 50 HP,  Three phase, 380 - 480 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: C1 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P37KT4P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P37KT4P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P37K) 37 KW / 50 HP, Three phase, 380 - 480 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Dis…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P30KT4P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P30K) 30 KW / 40 HP,  Three phase, 380 - 480 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: B2 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P30KT4P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P30KT4P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P30K) 30 KW / 40 HP, Three phase, 380 - 480 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Dis…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P22KT4P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P22K) 22 KW / 30 HP,  Three phase, 380 - 480 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: B2 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P22KT4P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P22KT4P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P22K) 22 KW / 30 HP, Three phase, 380 - 480 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Dis…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P18KT4P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P18K) 18.5 KW / 25 HP,  Three phase, 380 - 480 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: B1 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P18KT4P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P18KT4P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P18K) 18.5 KW / 25 HP, Three phase, 380 - 480 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains D…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P15KT4P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P15K) 15 KW / 20 HP,  Three phase, 380 - 480 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: B1 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P15KT4P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P15KT4P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P15K) 15 KW / 20 HP, Three phase, 380 - 480 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Dis…

    Add to Cart The item has been added
  • Quick view
    Frequency Converter FC-102P11KT4P55H2XGX3XXSXXXXAJBXCXXXXDX   VLT® HVAC Drive FC-102 (P11K) 11 KW / 15 HP,  Three phase, 380 - 480 VAC,IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Loc. Cont. Panel Not coated PCB, Mains Disconnect + Fuse Latest release std. SW. Frame: B1 BACnet MCA 109, No B Option No C1 option, No D option  Other options according to Model Code

    Danfoss

    FC-102P11KT4P55H2XGX3XXSXXXXAJBXCXXXXDX

    Frequency ConverterFC-102P11KT4P55H2XGX3XXSXXXXAJBXCXXXXDX VLT® HVAC Drive FC-102(P11K) 11 KW / 15 HP, Three phase, 380 - 480 VAC,IP55 / Type12 BackplateRFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Dis…

    Add to Cart The item has been added
Items 3541 to 3560 of 227591 total
  • Previous
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • Next

Footer Start

Categories

  • Drives
  • Rosemount

Brands

  • Danfoss
  • VACON
  • DANFOSS DRIVES
  • Danfoss Spares Parts
  • Rosemount
  • VACON Spares
  • View All

Further Info.

  • About us
  • Contact us
  • Brands
  • Sitemap

Customer Service

  • Terms of Conditions
  • Privacy Policy
  • Online Returns Policy

Subscribe to our newsletter

Store Info

www.invertwell.com
Email: info (a) invertwell.com

Connect With Us

© 2025 AC drives & controls.

Back To Top
×
×

Customer Login

If you are already registered, please log in.

Forgot your password?

Create your account and enjoy a new shopping experience.

Create A New Account
×
  • Danfoss
  • VACON
  • DANFOSS DRIVES
  • Danfoss Spares Parts
  • Rosemount
  • VACON Spares
  • Schneider Electric
  • Emerson
  • DANFOSS INDUSTRIAL AUTOMATION
  • DANFOSS REFRIGERATION
  • Siemens
  • Emotron
  • Eaton
  • Eura Drives Electronic
  • KEB
  • Fenner
  • HK INSTRUMENTS
Icon Hot
Quote per purchase volume in real time,
Quote per purchase volume in real time,
Get your QUOTE Get your Quote
Icon Hot