Zoom the image with the mouse

FC-102N315T4E5SH2TGCXXXSXXXXAXBXCXXXXDX

Write a Review
SKU:
132L7825

Frequency ConverterFC-102N315T4E5SH2TGCXXXSXXXXAXBXCXXXXDX VLT® HVAC Drive FC-102(N315) 315 KW / 450 HP, Three phase, 380 - 480 VAC,IP54/Type12,N3R Rd…

Ask for a Quotation

Ask for a Quotation

Feel free to inquire
  • Security Image 1
Description

Frequency Converter
FC-102N315T4E5SH2TGCXXXSXXXXAXBXCXXXXDX

VLT® HVAC Drive FC-102
(N315) 315 KW / 450 HP,
Three phase, 380 - 480 VAC,IP54/Type12,N3R Rdy+Heat
RFI Filter
Safe Stop
Graphical Loc. Cont. Panel
Coated PCB, No Mains Option
Latest release std. SW.
Frame: D2H
No A Option, No B Option
No C1 option, No D option

Other options according to Model Code

Model code: FC-102N315T4E5SH2TGCXXXSXXXXAXBXCXXXXDX

Danfoss VLT® HVAC Drive FC-102 Drive is dedicated toventilation, heating, and refrigeration applications. With a wide rangeof powerful standard and optional features, the Drive provides th...

Gross weight 125.3 Kilogram
Net weight 125 Kilogram
EAN 5714853894239

 

Product View (Switch) GLBL Global (Standard)
Product Group FC- VLT® HVAC Drive FC-
Series 102 102
Power Rating N315 (N315) 315 KW / 450 HP
Phase T Three phase
Mains Voltage 4 380 - 480 VAC
Enclosure E5S IP54/Type12,N3R Rdy+Heat
RFI Filter H2 RFI Filter
Brake - Safe Stop T Safe Stop
LCP G Graphical Loc. Cont. Panel
Coating PCB C Coated PCB
Mains Option X No Mains Option
Adaptation A X Standard Cable Entries
Adaptation B X No adaptation
Software Release SXXX Latest release std. SW.
Software Language Pack X Standard Language Pack
A Option AX No A Option
B Option BX No B Option
C0 Option MCO CX No C0 option
C1 Option X No C1 option
C Option Software XX No software option
D Option DX No D option
Frame Size D2H D2H
Product Catalog NO_VIEW NO VIEW
Typecode Part 1 FC-102N315T4E5SH2TGC
Typecode Part 2 XXXSXXXXAXBXCXXXXDX
Variant condition (ref. YV00)
































102_3N
4
60479
A_OPT_FC-102N315T4AX
BR_FC-102N315T4T
BR_FC-102N315T4TH2
B_OPT_FC-102N315T4BX
C0_OPT_FC-102N315T4CX
C1_OPT_FC-102N315T4X
COT_FC-102N315T4C
C_OPT_FC-102N315T4XX
D_OPT_FC-102N315T4DX
ECL_FC-102N315T4E5S
ECL_FC-102N315T4E5SH2
FC-102
FC-102N315T4
FC-102N315T4E5SH2
FRAME_D2H
HDW21_FC-102N315T4X
HDW21_FC-102N315T4XH2
HDW22_FC-102N315T4X
HDW22_FC-102N315T4XH2
HDW23_FC-102N315T4X
HDW23_FC-102N315T4XH2
IN_POWER_GROUP_3
LCP_FC-102N315T4G
N315
POWER_GROUP_3
RFI_FC-102N315T4H2
RU_POWER_GROUP_3
SV_FC-102N315T4SXXX
SV_FC-102SXXX
SV_FC-102SXXXD2H
VLT
Variant condition (Purch)
































102_3N
4
60479
A_OPT_FC-102N315T4AX
BR_FC-102N315T4T
BR_FC-102N315T4TH2
B_OPT_FC-102N315T4BX
C0_OPT_FC-102N315T4CX
C1_OPT_FC-102N315T4X
COT_FC-102N315T4C
C_OPT_FC-102N315T4XX
D_OPT_FC-102N315T4DX
ECL_FC-102N315T4E5S
ECL_FC-102N315T4E5SH2
FC-102
FC-102N315T4
FC-102N315T4E5SH2
FRAME_D2H
HDW21_FC-102N315T4X
HDW21_FC-102N315T4XH2
HDW22_FC-102N315T4X
HDW22_FC-102N315T4XH2
HDW23_FC-102N315T4X
HDW23_FC-102N315T4XH2
IN_POWER_GROUP_3
LCP_FC-102N315T4G
N315
POWER_GROUP_3
RFI_FC-102N315T4H2
RU_POWER_GROUP_3
SV_FC-102N315T4SXXX
SV_FC-102SXXX
SV_FC-102SXXXD2H
VLT
Power 110% (NO) [KW] 315 315
Height [mm] 1060,0 1060,0
Width w/ no C options [mm] 420,0 420,0
Depth [mm] 378,0 378,0
Depth with Option A/B [mm] 378,0 378,0
kVA 407 407
Power Loss NO [W] 6663 6663
Power Loss NO [W] 5703 5703
Continuous Current (NO) [A] 588 588
Intermittent Current (NO) [A] 647 647
Continuous Current (NO) [A] 535 535
Intermittent Current (NO) [A] 588 588
Calculated Gross Weight [kg] 125.3
Calculated Net Weight [kg] 125
ECCN EU Y901 Y901
ECCN US 3A999.a 3A999.a
Plant from Orderline F605 F605
Vendor ERR01 Cannot Determine Vendor
Recommended Factory ERR01 Cannot Determine Vendor
Modelcode01 FC-102N315T4E5SH2TGC
Modelcode02 XXXSXXXXAXBXCXXXXDX