Description
                
                    
			
		
					
	
		
			
			
			
		
					
	
		
			
			
                
            
    Frequency Converter
FC-102P30KT4E55H2XNCXXXSXXXXAXBXCXXXXDX
 
VLT® HVAC Drive FC-102
(P30K) 30 KW / 40 HP, 
Three phase, 380 - 480 VAC,IP55 / Type 12
RFI Filter
No brake chopper
Numerical Loc. Cont. Panel
Coated PCB, No Mains Option
Latest release std. SW.
Frame: B2
No A Option, No B Option
No C1 option, No D option
Other options according to Model Code
	
		Model code:
	
	FC-102P30KT4E55H2XNCXXXSXXXXAXBXCXXXXDX
	
Danfoss VLT® HVAC Drive FC-102 Drive is dedicated toventilation, heating, and refrigeration applications. With a wide rangeof powerful standard and optional features, the Drive provides th...
| Gross weight | 31.03 Kilogram | ||
| Net weight | 27.47 Kilogram | ||
| Volume | 105.71 Liter | ||
| EAN | 5702427510746 | 
| Product View (Switch) | GLBL | Global (Standard) | |
| Product Group | FC- | VLT® HVAC Drive FC- | |
| Series | 102 | 102 | |
| Power Rating | P30K | (P30K) 30 KW / 40 HP | |
| Phase | T | Three phase | |
| Mains Voltage | 4 | 380 - 480 VAC | |
| Enclosure | E55 | IP55 / Type 12 | |
| RFI Filter | H2 | RFI Filter | |
| Brake - Safe Stop | X | No brake chopper | |
| LCP | N | Numerical Loc. Cont. Panel | |
| Coating PCB | C | Coated PCB | |
| Mains Option | X | No Mains Option | |
| Adaptation A | X | Standard Cable Entries | |
| Adaptation B | X | No adaptation | |
| Software Release | SXXX | Latest release std. SW. | |
| Software Language Pack | X | Standard Language Pack | |
| A Option | AX | No A Option | |
| B Option | BX | No B Option | |
| C0 Option MCO | CX | No C0 option | |
| C1 Option | X | No C1 option | |
| C Option Software | XX | No software option | |
| D Option | DX | No D option | |
| Frame Size | B2 | B2 | |
| Product Catalog | NO_VIEW | NO VIEW | |
| Typecode Part 2 | XXXSXXXXAXBXCXXXXDX | ||
| Power 110% (NO) [KW] | 30 | 30 | |
| Height [mm] | 664,0 | 664,0 | |
| Width w/ no C options [mm] | 243,0 | 243,0 | |
| Depth [mm] | 261,0 | 261,0 | |
| Depth with Option A/B [mm] | 261,0 | 261,0 | |
| kVA | 42.3 | 42.3 | |
| Power Loss NO [W] | 698 | 698 | |
| Power Loss NO [W] | 698 | 698 | |
| Continuous Current (NO) [A] | 61 | 61 | |
| Intermittent Current (NO) [A] | 67.1 | 67.1 | |
| Continuous Current (NO) [A] | 52 | 52 | |
| Intermittent Current (NO) [A] | 57.2 | 57.2 | |
| Calculated Gross Weight [kg] | 31.03 | ||
| Calculated Net Weight [kg] | 27.47 | ||
| ECCN EU | Y901 | Y901 | |
| ECCN US | 3A999.a | 3A999.a | |
| Vendor | ERR01 | Cannot Determine Vendor | |
| Recommended Factory | ERR01 | Cannot Determine Vendor | |
| Modelcode01 | FC-102P30KT4E55H2XNC | ||
| Modelcode02 | XXXSXXXXAXBXCXXXXDX | ||
| Recommended Plant | ERR01 | ERR01 | 
 
 
		    			
 
  
  
                                         
                                 
             
         
                ![Frequency converter FC-302N160T5E21H2XLC7XXSXXXXA0B2CXXXXDX   VLT® AutomationDrive FC-302 (N160) 160 KW / 250 HP,  Three phase, 380 - 500 VAC,IP21 / Type 1 RFI Filter No brake chopper Graphical LCP + USB Coated PCB, Fuse Latest release std. SW. Frame: D2H PROFIBUS DP MCA 101, MCB-112 PTC Therm. Card No C1 option, No D option ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db] Other options according to Model code Frequency converter FC-302N160T5E21H2XLC7XXSXXXXA0B2CXXXXDX   VLT® AutomationDrive FC-302 (N160) 160 KW / 250 HP,  Three phase, 380 - 500 VAC,IP21 / Type 1 RFI Filter No brake chopper Graphical LCP + USB Coated PCB, Fuse Latest release std. SW. Frame: D2H PROFIBUS DP MCA 101, MCB-112 PTC Therm. Card No C1 option, No D option ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db] Other options according to Model code](https://cdn11.bigcommerce.com/s-8i0vit1dn8/images/stencil/262x262/products/2222021/1270984/ID263146901775-0101_preview__88387.1748938903.jpg?c=1) 
             
             
             
             
            