Zoom the image with the mouse

FC-103N315T4E5MH4TGCXXXSXXXXAXBXCXXXXDX

Write a Review
SKU:
134H8139
£29,992.69

Frequency converterFC-103N315T4E5MH4TGCXXXSXXXXAXBXCXXXXDX VLT® Refrigeration Drive FC-103(N315) 315 KW / 450 HP, Three phase, 380 - 480 VAC,IP54/Type…

Adding to cart… The item has been added
Ask for a Quotation

Ask for a Quotation

Feel free to inquire
  • Security Image 1
Description

Frequency converter
FC-103N315T4E5MH4TGCXXXSXXXXAXBXCXXXXDX

VLT® Refrigeration Drive FC-103
(N315) 315 KW / 450 HP,
Three phase, 380 - 480 VAC,IP54/Type 12+main shield
RFI filter Class A1
Safe Stop
Graphical Loc. Cont. Panel
Coated PCB, No Mains Option
Latest release std. SW.
No A Option, No B Option
No C1 option, No D option
Frame: D2H
Other options according to Model code

Model code: FC-103N315T4E5MH4TGCXXXSXXXXAXBXCXXXXDX

Whether you want to operate compressors, pumps or fans, the VLT®Refrigeration Drive FC 103 gives you the opportunity to save energy andextend the lifetime of the components.

Gross weight 153 Kilogram
Net weight 138 Kilogram
Volume 378.972 Liter
EAN 5710107732692

 

Product View (Switch) GLBL Global (Standard)
Product Group FC- VLT® Refrigeration Drive
Series 103 103
Power Rating N315 (N315) 315 KW / 450 HP
Phase T Three phase
Mains Voltage 4 380 - 480 VAC
Enclosure E5M IP54/Type 12+main shield
RFI Filter H4 RFI filter Class A1
Brake - Safe Stop T Safe Stop
LCP G Graphical Loc. Cont. Panel
Coating PCB C Coated PCB
Mains Option X No Mains Option
Adaptation A X Standard Cable Entries
Adaptation B X No adaptation
Software Release SXXX Latest release std. SW.
Software Language Pack X Standard Language Pack
A Option AX No A Option
B Option BX No B Option
C0 Option MCO CX No C0 option
C1 Option X No C1 option
C Option Software XX No software option
D Option DX No D option
Frame Size D2H D2H
Product Catalog NO_VIEW NO VIEW
Typecode Part 2 XXXSXXXXAXBXCXXXXDX
Power 110% (NO) [KW] 315 315
Height [mm] 1060,0 1060,0
Width w/ no C options [mm] 420,0 420,0
Depth [mm] 378,0 378,0
Depth with Option A/B [mm] 378,0 378,0
kVA 407 407
Power Loss NO [W] 6663 6663
Power Loss NO [W] 5703 5703
Continuous Current (NO) [A] 588 588
Intermittent Current (NO) [A] 647 647
Continuous Current (NO) [A] 535 535
Intermittent Current (NO) [A] 588 588
Calculated Gross Weight [kg] 125.3
Calculated Net Weight [kg] 125
ECCN EU Y901 Y901
ECCN US 3A999.a 3A999.a
Recommended Plant ERR01 ERR01
Vendor ERR01 Cannot Determine Vendor
Recommended Factory ERR01 Cannot Determine Vendor
Modelcode01 FC-103N315T4E5MH4TGC
Modelcode02 XXXSXXXXAXBXCXXXXDX
DrivePro category EXCH Exchange Unit
Bottom Banner