Zoom the image with the mouse

FC-103N450T4E20H4XGC7XXSXXXXAXBKCXXXXD0

Write a Review
SKU:
136U0371

Frequency converterFC-103N450T4E20H4XGC7XXSXXXXAXBKCXXXXD0 VLT® Refrigeration Drive FC-103(N450)450 KW / 600 HP, Three phase, 380 - 480 VAC,(E20) IP20…

Ask for a Quotation

Ask for a Quotation

Feel free to inquire
  • Security Image 1
Description

Frequency converter
FC-103N450T4E20H4XGC7XXSXXXXAXBKCXXXXD0

VLT® Refrigeration Drive FC-103
(N450)450 KW / 600 HP,
Three phase, 380 - 480 VAC,(E20) IP20 / Chassis
RFI filter Class A1
No brake chopper
Graphical Loc. Cont. Panel
Coated PCB, Fuse
Latest release std. SW.
No A Option, MCB-101 General purpose I/O
No C1 option, 24V DC backup
Frame: E3H
Other options according to Model code

Model code: FC-103N450T4E20H4XGC7XXSXXXXAXBKCXXXXD0

Whether you want to operate compressors, pumps or fans, the VLT®Refrigeration Drive FC 103 gives you the opportunity to save energy andextend the lifetime of the components.

Gross weight 272.3 Kilogram
Net weight 272 Kilogram
EAN 5710108983598

 

Product View (Switch) GLBL Global (Standard)
Product Group FC- VLT® Refrigeration Drive
Series 103 103
Power Rating N450 (N450)450 KW / 600 HP
Phase T Three phase
Mains Voltage 4 380 - 480 VAC
Enclosure E20 (E20) IP20 / Chassis
RFI Filter H4 RFI filter Class A1
Brake - Safe Stop X No brake chopper
LCP G Graphical Loc. Cont. Panel
Coating PCB C Coated PCB
Mains Option 7 Fuse
Adaptation A X Standard Cable Entries
Adaptation B X No adaptation
Software Release SXXX Latest release std. SW.
Software Language Pack X Standard Language Pack
A Option AX No A Option
B Option BK MCB-101 General purpose I/O
C0 Option MCO CX No C0 option
C1 Option X No C1 option
C Option Software XX No software option
D Option D0 24V DC backup
Frame Size E3H E3H
Product Catalog NO_VIEW NO VIEW
Typecode Part 2 7XXSXXXXAXBKCXXXXD0
Power 110% (NO) [KW] 450 450
Height [mm] 1578,0 1578,0
Width w/ no C options [mm] 507,0 507,0
Depth [mm] 482,0 482,0
Depth with Option A/B [mm] 482,0 482,0
kVA 554 554
Power Loss NO [W] 8783 8783
Power Loss NO [W] 7969 7969
Continuous Current (NO) [A] 800 800
Intermittent Current (NO) [A] 880 880
Continuous Current (NO) [A] 730 730
Intermittent Current (NO) [A] 803 803
Calculated Gross Weight [kg] 272.3
Calculated Net Weight [kg] 272
ECCN EU Y901 Y901
ECCN US 3A999.a 3A999.a
Recommended Plant ERR01 ERR01
Vendor ERR01 Cannot Determine Vendor
Recommended Factory ERR01 Cannot Determine Vendor
Modelcode01 FC-103N450T4E20H4XGC
Modelcode02 7XXSXXXXAXBKCXXXXD0
Bottom Banner