Zoom the image with the mouse

FC-103N450T4E5MH2TGC3XQSXXXXAQBXCXXXXDX

Write a Review
SKU:
132H3103

Frequency converterFC-103N450T4E5MH2TGC3XQSXXXXAQBXCXXXXDX VLT® Refrigeration Drive FC-103(N450)450 KW / 600 HP, Three phase, 380 - 480 VAC,IP54/Type …

Ask for a Quotation

Ask for a Quotation

Feel free to inquire
  • Security Image 1
Description

Frequency converter
FC-103N450T4E5MH2TGC3XQSXXXXAQBXCXXXXDX

VLT® Refrigeration Drive FC-103
(N450)450 KW / 600 HP,
Three phase, 380 - 480 VAC,IP54/Type 12+main shield
RFI filter Class A2
Safe Stop
Graphical Loc. Cont. Panel
Coated PCB, Mains Disconnect + Fuse
Latest release std. SW.
Modbus TCP MCA 122, No B Option
No C1 option, No D option
Frame: E1H
Other options according to Model code

Model code: FC-103N450T4E5MH2TGC3XQSXXXXAQBXCXXXXDX

Whether you want to operate compressors, pumps or fans, the VLT®Refrigeration Drive FC 103 gives you the opportunity to save energy andextend the lifetime of the components.

Gross weight 296 Kilogram
Net weight 256 Kilogram
EAN 5714853319312

 

Product View (Switch) GLBL Global (Standard)
Product Group FC- VLT® Refrigeration Drive
Series 103 103
Power Rating N450 (N450)450 KW / 600 HP
Phase T Three phase
Mains Voltage 4 380 - 480 VAC
Enclosure E5M IP54/Type 12+main shield
RFI Filter H2 RFI filter Class A2
Brake - Safe Stop T Safe Stop
LCP G Graphical Loc. Cont. Panel
Coating PCB C Coated PCB
Mains Option 3 Mains Disconnect + Fuse
Adaptation A X Standard Cable Entries
Adaptation B Q Heat-sink access
Software Release SXXX Latest release std. SW.
Software Language Pack X Standard Language Pack
A Option AQ Modbus TCP MCA 122
B Option BX No B Option
C0 Option MCO CX No C0 option
C1 Option X No C1 option
C Option Software XX No software option
D Option DX No D option
Frame Size E1H E1H
Product Catalog NO_VIEW NO VIEW
Typecode Part 2 3XQSXXXXAQBXCXXXXDX
Power 110% (NO) [KW] 450 450
Height [mm] 2000,0 2000,0
Width w/ no C options [mm] 600,0 600,0
Depth [mm] 510,0 510,0
Depth with Option A/B [mm] 510,0 510,0
kVA 554 554
Power Loss NO [W] 8783 8783
Power Loss NO [W] 7969 7969
Continuous Current (NO) [A] 800 800
Intermittent Current (NO) [A] 880 880
Continuous Current (NO) [A] 730 730
Intermittent Current (NO) [A] 803 803
Calculated Gross Weight [kg] 295.3
Calculated Net Weight [kg] 295
ECCN EU Y901 Y901
ECCN US 3A999.a 3A999.a
Recommended Plant ERR01 ERR01
Vendor ERR01 Cannot Determine Vendor
Recommended Factory ERR01 Cannot Determine Vendor
Modelcode01 FC-103N450T4E5MH2TGC
Modelcode02 3XQSXXXXAQBXCXXXXDX
Bottom Banner