Frequency converterFC-103N500T7E20H2TGC7XXSXXXXAXBKCXXXXDX VLT® Refrigeration Drive FC-103(N500)500 KW / 650 HP, Specific Ratings: 400kW@525-550V, 500…

Ask for a Quotation

Ask for a Quotation

Feel free to inquire
  • Security Image 1
Description

Frequency converter
FC-103N500T7E20H2TGC7XXSXXXXAXBKCXXXXDX

VLT® Refrigeration Drive FC-103
(N500)500 KW / 650 HP, Specific Ratings: 400kW@525-550V, 500HP@575V, 500kW@690V
Three phase, 525 - 690 VAC *,(E20) IP20 / Chassis
RFI filter Class A2
Safe Stop
Graphical Loc. Cont. Panel
Coated PCB, Fuse
Latest release std. SW.
No A Option, MCB-101 General purpose I/O
No C1 option, No D option
Frame: E3H
Other options according to Model code

Model code: FC-103N500T7E20H2TGC7XXSXXXXAXBKCXXXXDX

Whether you want to operate compressors, pumps or fans, the VLT®Refrigeration Drive FC 103 gives you the opportunity to save energy andextend the lifetime of the components.

Gross weight 272.3 Kilogram
Net weight 272 Kilogram
EAN 5714853284559

 

Product View (Switch) GLBL Global (Standard)
Product Group FC- VLT® Refrigeration Drive
Series 103 103
Power Rating N500 (N500)500 KW / 650 HP
Phase T Three phase
Mains Voltage 7 525 - 690 VAC *
Enclosure E20 (E20) IP20 / Chassis
RFI Filter H2 RFI filter Class A2
Brake - Safe Stop T Safe Stop
LCP G Graphical Loc. Cont. Panel
Coating PCB C Coated PCB
Mains Option 7 Fuse
Adaptation A X Standard Cable Entries
Adaptation B X No adaptation
Software Release SXXX Latest release std. SW.
Software Language Pack X Standard Language Pack
A Option AX No A Option
B Option BK MCB-101 General purpose I/O
C0 Option MCO CX No C0 option
C1 Option X No C1 option
C Option Software XX No software option
D Option DX No D option
Frame Size E3H E3H
Product Catalog NO_VIEW NO VIEW
Typecode Part 2 7XXSXXXXAXBKCXXXXDX
Power 110% (NO) [KW] 500 500
Height [mm] 1578,0 1578,0
Width w/ no C options [mm] 507,0 507,0
Depth [mm] 482,0 482,0
Depth with Option A/B [mm] 482,0 482,0
kVA 598 598
Power Loss NO [W] 6879 6879
Power Loss NO [W] 6715 6715
Continuous Current (NO) [A] 523 523
Intermittent Current (NO) [A] 575 575
Continuous Current (NO) [A] 500 500
Intermittent Current (NO) [A] 550 550
Power Rating at 525-550V 400kW 400kW
Power Rating at 575V 500HP 500HP
Power Rating at 690V 500kW 500kW
Calculated Gross Weight [kg] 272.3
Calculated Net Weight [kg] 272
ECCN EU Y901 Y901
ECCN US 3A999.a 3A999.a
Recommended Plant ERR01 ERR01
Vendor ERR01 Cannot Determine Vendor
Recommended Factory ERR01 Cannot Determine Vendor
Modelcode01 FC-103N500T7E20H2TGC
Modelcode02 7XXSXXXXAXBKCXXXXDX