Frequency converter
FC-202N200T4E54H4TGC7XXSXXXXALB2CXXXXD0
VLT® AQUA Drive FC-202
(N200) 200 KW / 300 HP,
Three phase, 380 - 480 VAC,(E54) IP54 / Type 12
RFI class A1 (C2)
Safe Stop
Graphical Loc. Cont. Panel
Coated PCB, Fuse
Latest release std. SW.
Frame: D2H
PROFINET MCA 120, MCB-112 PTC Therm. Card
No C1 option, MCB-107 24V DC backup
ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Other options according to Model code
Danfoss VLT® AQUA Drive is dedicated to water and wastewaterapplications. With a wide range of powerful standard and optionalfeatures, the VLT® AQUA Drive provides the lowest overall cost of...
Gross weight | 125.3 Kilogram | ||
Net weight | 125 Kilogram | ||
EAN | 5715253427300 |
Product View (Switch) | GLBL | Global (Standard) | |
Product Group | FC- | VLT® AQUA Drive FC- | |
Series | 202 | 202 | |
Power Rating | N200 | (N200) 200 KW / 300 HP | |
Phase | T | Three phase | |
Mains Voltage | 4 | 380 - 480 VAC | |
Enclosure | E54 | (E54) IP54 / Type 12 | |
RFI Filter | H4 | RFI class A1 (C2) | |
Brake - Safe Stop | T | Safe Stop | |
LCP | G | Graphical Loc. Cont. Panel | |
Coating PCB | C | Coated PCB | |
Mains Option | 7 | Fuse | |
Adaptation A | X | Standard Cable Entries | |
Adaptation B | X | No adaptation | |
Software Release | SXXX | Latest release std. SW. | |
Software Language Pack | X | Standard Language Pack | |
A Option | AL | PROFINET MCA 120 | |
B Option | B2 | MCB-112 PTC Therm. Card | |
C0 Option MCO | CX | No C0 option | |
C1 Option | X | No C1 option | |
C Option Software | XX | No software option | |
D Option | D0 | MCB-107 24V DC backup | |
Frame Size | D2H | D2H | |
Typecode Part 2 | 7XXSXXXXALB2CXXXXD0 | ||
Product Catalog | NO_VIEW | NO VIEW | |
Power 150% (HO) [KW] | 160 | 160 | |
Power 110% (NO) [KW] | 200 | 200 | |
Height [mm] | 1060,0 | 1060,0 | |
Width w/ no C options [mm] | 420,0 | 420,0 | |
Depth [mm] | 378,0 | 378,0 | |
Depth with Option A/B [mm] | 378,0 | 378,0 | |
kVA | 274 | 274 | |
Power Loss NO [W] | 4116 | 4116 | |
Power Loss NO [W] | 3569 | 3569 | |
Power Loss HO [W] | 3093 | 3093 | |
Power Loss HO [W] | 2872 | 2872 | |
Continuous Current (NO) [A] | 395 | 395 | |
Intermittent Current (NO) [A] | 435 | 435 | |
Continuous Current (NO) [A] | 361 | 361 | |
Intermittent Current (NO) [A] | 397 | 397 | |
Continuous Current (HO) [A] | 315 | 315 | |
Intermittent Current (HO) [A] | 472 | 472 | |
Continuous Current (HO) [A] | 302 | 302 | |
Intermittent Current (HO) [A] | 453 | 453 | |
ATEX Marking 1 | ATEX: II (2) G [Ex eb Gb] [Ex | ATEX: II (2) G [Ex eb Gb] [Ex | |
ATEX Marking 2 | db Gb] / II (2) D [Ex tb Db] | db Gb] / II (2) D [Ex tb Db] | |
Calculated Gross Weight [kg] | 0.44 | ||
Calculated Net Weight [kg] | 0.44 | ||
ECCN EU | Y901 | Y901 | |
ECCN US | 3A999.a | 3A999.a | |
Plant from Orderline | D801 | D801 | |
Vendor | ERR01 | Cannot Determine Vendor | |
Recommended Factory | ERR01 | Cannot Determine Vendor | |
Modelcode01 | FC-202N200T4E54H4TGC | ||
Modelcode02 | 7XXSXXXXALB2CXXXXD0 |