Zoom the image with the mouse

FC-202N200T4E5MH4TGC3XXLX1XXAXBXCXXXXDX

Write a Review
SKU:
132N5130

Frequency converterFC-202N200T4E5MH4TGC3XXLX1XXAXBXCXXXXDX VLT® AQUA Drive FC-202(N200) 200 KW / 300 HP, Three phase, 380 - 480 VAC,IP54/Type 12+main …

Ask for a Quotation

Ask for a Quotation

Feel free to inquire
  • Security Image 1
Description

Frequency converter
FC-202N200T4E5MH4TGC3XXLX1XXAXBXCXXXXDX

VLT® AQUA Drive FC-202
(N200) 200 KW / 300 HP,
Three phase, 380 - 480 VAC,IP54/Type 12+main shield
RFI class A1 (C2)
Safe Stop
Graphical Loc. Cont. Panel
Coated PCB, Mains Disconnect + Fuse
Condition Based Monitoring CBM
Frame: D7H
No A Option, No B Option
No C1 option, No D option

Other options according to Model code

Model code: FC-202N200T4E5MH4TGC3XXLX1XXAXBXCXXXXDX

Danfoss VLT® AQUA Drive is dedicated to water and wastewaterapplications. With a wide range of powerful standard and optionalfeatures, the VLT® AQUA Drive provides the lowest overall cost of...

Gross weight 200.3 Kilogram
Net weight 200 Kilogram
EAN 5715253091358

 

Product View (Switch) GLBL Global (Standard)
Product Group FC- VLT® AQUA Drive FC-
Series 202 202
Power Rating N200 (N200) 200 KW / 300 HP
Phase T Three phase
Mains Voltage 4 380 - 480 VAC
Enclosure E5M IP54/Type 12+main shield
RFI Filter H4 RFI class A1 (C2)
Brake - Safe Stop T Safe Stop
LCP G Graphical Loc. Cont. Panel
Coating PCB C Coated PCB
Mains Option 3 Mains Disconnect + Fuse
Adaptation A X Standard Cable Entries
Adaptation B X No adaptation
Software Release LX1X Condition Based Monitoring CBM
Software Language Pack X Standard Language Pack
A Option AX No A Option
B Option BX No B Option
C0 Option MCO CX No C0 option
C1 Option X No C1 option
C Option Software XX No software option
D Option DX No D option
Frame Size D7H D7H
Typecode Part 2 3XXLX1XXAXBXCXXXXDX
Product Catalog NO_VIEW NO VIEW
Power 150% (HO) [KW] 160 160
Power 110% (NO) [KW] 200 200
Height [mm] 1978,0 1978,0
Width w/ no C options [mm] 420,0 420,0
Depth [mm] 386,0 386,0
Depth with Option A/B [mm] 386,0 386,0
kVA 274 274
Power Loss NO [W] 4116 4116
Power Loss NO [W] 3569 3569
Power Loss HO [W] 3093 3093
Power Loss HO [W] 2872 2872
Continuous Current (NO) [A] 395 395
Intermittent Current (NO) [A] 435 435
Continuous Current (NO) [A] 361 361
Intermittent Current (NO) [A] 397 397
Continuous Current (HO) [A] 315 315
Intermittent Current (HO) [A] 472 472
Continuous Current (HO) [A] 302 302
Intermittent Current (HO) [A] 453 453
Calculated Gross Weight [kg] 0.09
Calculated Net Weight [kg] 0.09
ECCN EU Y901 Y901
ECCN US 3A999.a 3A999.a
Plant from Orderline F605 F605
Vendor ERR01 Cannot Determine Vendor
Recommended Factory ERR01 Cannot Determine Vendor
Modelcode01 FC-202N200T4E5MH4TGC
Modelcode02 3XXLX1XXAXBXCXXXXDX