Zoom the image with the mouse

FC-202N400T4E5MH2TGC7XXSXXXXAXBXCXXXXD0

Write a Review
SKU:
132N9999

Frequency converterFC-202N400T4E5MH2TGC7XXSXXXXAXBXCXXXXD0 VLT® AQUA Drive FC-202(N400) 400 KW / 550 HP, Three phase, 380 - 480 VAC,IP54/Type 12+main …

Ask for a Quotation

Ask for a Quotation

Feel free to inquire
  • Security Image 1
Description

Frequency converter
FC-202N400T4E5MH2TGC7XXSXXXXAXBXCXXXXD0

VLT® AQUA Drive FC-202
(N400) 400 KW / 550 HP,
Three phase, 380 - 480 VAC,IP54/Type 12+main shield
RFI Filter
Safe Stop
Graphical Loc. Cont. Panel
Coated PCB, Fuse
Latest release std. SW.
Frame: E1H
No A Option, No B Option
No C1 option, MCB-107 24V DC backup

Other options according to Model code

Model code: FC-202N400T4E5MH2TGC7XXSXXXXAXBXCXXXXD0

Danfoss VLT® AQUA Drive is dedicated to water and wastewaterapplications. With a wide range of powerful standard and optionalfeatures, the VLT® AQUA Drive provides the lowest overall cost of...

Gross weight 295.3 Kilogram
Net weight 295 Kilogram
EAN 5715253146942

 

Product View (Switch) GLBL Global (Standard)
Product Group FC- VLT® AQUA Drive FC-
Series 202 202
Power Rating N400 (N400) 400 KW / 550 HP
Phase T Three phase
Mains Voltage 4 380 - 480 VAC
Enclosure E5M IP54/Type 12+main shield
RFI Filter H2 RFI Filter
Brake - Safe Stop T Safe Stop
LCP G Graphical Loc. Cont. Panel
Coating PCB C Coated PCB
Mains Option 7 Fuse
Adaptation A X Standard Cable Entries
Adaptation B X No adaptation
Software Release SXXX Latest release std. SW.
Software Language Pack X Standard Language Pack
A Option AX No A Option
B Option BX No B Option
C0 Option MCO CX No C0 option
C1 Option X No C1 option
C Option Software XX No software option
D Option D0 MCB-107 24V DC backup
Frame Size E1H E1H
Typecode Part 2 7XXSXXXXAXBXCXXXXD0
Product Catalog NO_VIEW NO VIEW
Power 150% (HO) [KW] 355 355
Power 110% (NO) [KW] 400 400
Height [mm] 2000,0 2000,0
Width w/ no C options [mm] 600,0 600,0
Depth [mm] 510,0 510,0
Depth with Option A/B [mm] 510,0 510,0
kVA 516 516
Power Loss NO [W] 8036 8036
Power Loss NO [W] 6933 6933
Power Loss HO [W] 6851 6851
Power Loss HO [W] 5846 5846
Continuous Current (NO) [A] 745 745
Intermittent Current (NO) [A] 820 820
Continuous Current (NO) [A] 678 678
Intermittent Current (NO) [A] 746 746
Continuous Current (HO) [A] 658 658
Intermittent Current (HO) [A] 987 987
Continuous Current (HO) [A] 590 590
Intermittent Current (HO) [A] 885 885
Calculated Gross Weight [kg] 0.14
Calculated Net Weight [kg] 0.14
ECCN EU Y901 Y901
ECCN US 3A999.a 3A999.a
Plant from Orderline B901 B901
Vendor ERR01 Cannot Determine Vendor
Recommended Factory ERR01 Cannot Determine Vendor
Allowed Plants E101
E102
E103
E104
E105
F605
(E101) Dandenong Distribution
(E102) Derrimut Distribution
(E103) Sydney Distribution
(E104) Brisbane Distribution
(E105) Perth Distribution
(F605) Loves Park SAles
Modelcode01 FC-202N400T4E5MH2TGC
Modelcode02 7XXSXXXXAXBXCXXXXD0
Bottom Banner