Frequency converter
FC-302N160T7E20H2BGRAXXSXXXXAXBXCXXXXDX
VLT® AutomationDrive FC-302
(N160) 160 KW / 250 HP, Specific Ratings: 132kW@525-550V, 200HP@575V, 160kW@690V
Three phase, 525 - 690 VAC *,(E20) IP20 / Chassis
RFI Filter
Brake chopper
Graphical Loc. Cont. Panel
Coated PCB 3C3 + Ruggedised, Fuse + Loadsharing
Latest release std. SW.
Frame: D4H
No A Option, No B Option
No C1 option, No D option
Other options according to Model code
The VLT® AutomationDrive represents a single drive concept that controlsthe entire range of operations from ordinary to servo like applicationson any machine or production line.
Gross weight | 125.3 Kilogram | ||
Net weight | 125 Kilogram | ||
EAN | 5710107894178 |
Product View (Switch) | GLBL | Global (Standard) | |
Product Group | FC- | VLT® AutomationDrive FC- | |
Series | 302 | 302 | |
Power Rating | N160 | (N160) 160 KW / 250 HP | |
Phase | T | Three phase | |
Mains Voltage | 7 | 525 - 690 VAC * | |
Possible rating issue | WARN01 | Possible Rating Issue: | |
Enclosure | E20 | (E20) IP20 / Chassis | |
RFI Filter | H2 | RFI Filter | |
Brake - Safe Stop | B | Brake chopper | |
LCP | G | Graphical Loc. Cont. Panel | |
Coating PCB | R | Coated PCB 3C3 + Ruggedised | |
Mains Option | A | Fuse + Loadsharing | |
Adaptation A | X | Standard Cable Entries | |
Adaptation B | X | No adaptation | |
Software Release | SXXX | Latest release std. SW. | |
Software Language Pack | X | Standard Language Pack | |
A Option | AX | No A Option | |
B Option | BX | No B Option | |
C0 Option MCO | CX | No C0 option | |
C1 Option | X | No C1 option | |
C Option Software | XX | No software option | |
D Option | DX | No D option | |
Frame Size | D4H | D4H | |
Typecode Part 2 | AXXSXXXXAXBXCXXXXDX | ||
Product Catalog | NO_VIEW | NO VIEW | |
Power 150% (HO) [KW] | 160 | 160 | |
Power 110% (NO) [KW] | 200 | 200 | |
Height [mm] | 1122,0 | 1122,0 | |
Height w/ Regen/Loadshare [mm] | 1268,0 | 1268,0 | |
Width w/ no C options [mm] | 350,0 | 350,0 | |
Depth [mm] | 375,0 | 375,0 | |
Depth with Option A/B [mm] | 375,0 | 375,0 | |
kVA | 229 | 229 | |
Power Loss NO [W] | 3074 | 3074 | |
Power Loss NO [W] | 3175 | 3175 | |
Power Loss HO [W] | 2361 | 2361 | |
Power Loss HO [W] | 2446 | 2446 | |
Continuous Current (NO) [A] | 253 | 253 | |
Intermittent Current (NO) [A] | 278 | 278 | |
Continuous Current (NO) [A] | 242 | 242 | |
Intermittent Current (NO) [A] | 266 | 266 | |
Continuous Current (HO) [A] | 201 | 201 | |
Intermittent Current (HO) [A] | 302 | 302 | |
Continuous Current (HO) [A] | 192 | 192 | |
Intermittent Current (HO) [A] | 288 | 288 | |
Power Rating at 525-550V | 132kW | 132kW | |
Power Rating at 575V | 200HP | 200HP | |
Power Rating at 690V | 160kW | 160kW | |
Calculated Gross Weight [kg] | 125.3 | ||
Calculated Net Weight [kg] | 125 | ||
ECCN EU | Y901 | Y901 | |
ECCN US | 3A999.a | 3A999.a | |
Vendor | ERR01 | Cannot Determine Vendor | |
Recommended Factory | ERR01 | Cannot Determine Vendor | |
Modelcode01 | FC-302N160T7E20H2BGR | ||
Modelcode02 | AXXSXXXXAXBXCXXXXDX | ||
Recommended Plant | ERR01 | ERR01 |