Description
iC7-Hybrid
System module, liquid-cooled
IC7-60SLDCB5-3240E00F4+AED1+AKFF+ANN1+AO20+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK03+BL25+DAHY
IP00/Open Type, Frame:3xDR12L
DC/DC converter module, 380-500 V AC / 465-800 V DC,3240 A
EMC category: C4 category
Control Panel 2.8 OPX20
Standard I/O: I/O and Relay Option OC7C1
Modbus TCP OS7MT
Functional Safety: None, not upgradable
Other options according to model code
Model code:
IC7-60SLDCB5-3240E00F4+AED1+AKFF+ANN1+AO20+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK03+BL25+DAHY
iC7-Hybrid is an enabler in electrification and hybridization applications. Use this power converter to integrate diverse energy sou
...
Gross weight | 822 Kilogram | ||
Net weight | 690 Kilogram | ||
EAN | 5715253784588 |
Product series | +DAHY | iC7-Hybrid | |
Product group | IC7-60 | iC7-60 | |
Product category | SL | System module, liquid-cooled | |
Product type | DC | DC/DC converter module | |
Salescode part 2 | +AED1+AKFF+ANN1 | +AED1+AKFF+ANN1 | |
Mains voltage | B5 | 380-500 V AC / 465-800 V DC | |
Salescode part 3 | +AO20+BAMT+BDC1+BEXX+BF20 | +AO20+BAMT+BDC1+BEXX+BF20 | |
Current rating | -3240 | 3240 A | |
Salescode part 4 | +BGK1+BH15+BK03+BL25 | +BGK1+BH15+BK03+BL25 | |
Power rating | XXX | Not relevant | |
Salescode part 5 | +DAHY | +DAHY | |
Protection rating | E00 | IP00/Open Type | |
EMC category | F4 | C4 category | |
Integration unit | +AED1 | Standard, with DC/DC filter | |
Mains input device | +AJXX | None | |
DC fuses and devices | +AKFF | DC bus fuses and source fuses | |
Cooling circuit connector type | +ANN1 | Push-in connection | |
Cooling circuit hose length | +AO20 | 2.0 m (6 ft) | |
Marine construction | +AFXX | None | |
Extra environmental protection | +AGCX | Coated boards | |
Communication interface, X1/X2 | +BAMT | Modbus TCP OS7MT | |
Communication interface, X0 | +BBEL | Ethernet port, no protocol | |
Standard I/O | +BDC1 | I/O and Relay Option OC7C1 | |
Functional safety | +BEXX | None, not upgradable | |
Control panel | +BF20 | Control Panel 2.8 OPX20 | |
Control panel mounting type | +BGK1 | Flush mount | |
Control panel cable length | +BH15 | 1.5 m (5 ft) | |
Control unit cable length | +BK03 | 0.3 m (1 ft), Fiber | |
StarCoupler board cable length | +BL25 | 2.5 m (8 ft), Fiber | |
Option slot A | +CAXX | None, without mounting p | |
Option slot B | +CBXX | None, without mounting plate | |
Option slot C | +CCXX | None, without mounting plate | |
Option slot D | +CDXX | None, without mounting plate | |
Option slot E | +CEXX | None, without mounting plate | |
Option slot F | +CFXX | None, without mounting plate | |
Option slot G | +CGXX | None, without mounting plate | |
Option slot H | +CHXX | None, without mounting plate | |
Option slot I | +CIXX | None, without mounting plate | |
Option slot J | +CJXX | None, without mounting plate | |
Language package | +EL01 | Global | |
Customer specific application | +DBXX | None | |
Additional drive features 1 | +DD1X | None | |
Additional drive features 2 | +DE2X | None | |
Additional drive features 3 | +DF3X | None | |
Additional drive features 4 | +DG4X | None | |
Additional drive features 5 | +DH5X | None | |
High speed enabled | +DI6X | No | |
Customization file package ID | +EAXXXXXX | No customization | |
Product software ID | +ECXXX | Latest released version | |
Technical documentation | +EGXX | None | |
Documentation language | +EHXX | Multi-language | |
Customer-specific label | +EJXX | None | |
Shipping package | +TACB | Cardboard box package | |
Product specific marine cert. | +VBXX | None | |
Frame designation | 3XDR12L | 3xDR12L | |
Modelcode01 | IC7-60SLDCB5-3240E00F4 | ||
Modelcode02 | +AED1+AKFF+ANN1 | ||
Modelcode03 | +AO20+BAMT+BDC1+BEXX+BF20 | ||
Modelcode04 | +BGK1+BH15+BK03+BL25 | ||
Modelcode06 | +DAHY | ||
Main unit Width | 3X235MM/9.3IN | 3X235MM/9.3IN | |
Main unit Height | 1282MM/50.5IN | 1282MM/50.5IN | |
Main unit Depth | 568MM/22.4IN | 568MM/22.4IN | |
Calculated Gross Weight [kg] | 822 | ||
Calculated Net Weight [kg] | 690 | ||
ECCN EU | Y901 | Y901 | |
ECCN US | 3A999.a | 3A999.a | |
check if complete | OK | OK | |
Cooling type | Liquid Cooled | Liquid Cooled | |
DC Bus current | 3308A(742VDC) | 3308A(742VDC) | |
DC Bus voltage | 465-800VDC | 465-800VDC | |
DC power | 2457KW(742VDC) | 2457KW(742VDC) | |
DC Source/load current | 3308A(742VDC) | 3308A(742VDC) | |
DC Source/load voltage | 0-VDC BUS | 0-VDC BUS | |
Enclosure rating | IP00 / OPEN TYPE | IP00 / OPEN TYPE | |
Help Counter | 1 | ||
Liquid temp. High Overload | 45°C/113°F | 45°C/113°F | |
Liquid temp. Low Overload | 45°C/113°F | 45°C/113°F | |
Liquid temp. Nominal load | 45°C/113°F | 45°C/113°F | |
Plant from Orderline | D801 | D801 | |
Product Catalog | NO_VIEW | NO VIEW | |
Product Category -DrivesSymbol | System module, liquid-cooled | System module, liquid-cooled | |
Product Type - DrivesSymbol | DC/DC converter module | DC/DC converter module | |
Product View (Switch) | GLBL | Global (Standard) | |
Salescode part 1 | IC7-60SLDCB5-3240E00F4 | IC7-60SLDCB5-3240E00F4 | |
Short circuit current rating | 100kA | 100kA | |
Storage temperature | -40...70°C/-40...158°F | -40...70°C/-40...158°F | |
Typecode Part 2 | -000155858 | ||
Vendor | ERR01 | Cannot Determine Vendor |