iC7-Marine
System module, liquid-cooled
IC7-60SLINB5-416AE00F4+AE10+AKFX+ANN1 +AO20+BAMT+BDC1+BEXX+BF20+BGK1+BH25+BK15+CAM0+CBT0 +CCC1+CDX0+CEX0+CFX0+DAMA +EGIN+EHEN +VBDN
IP00/Open Type, Frame: IR10L
Inverter module, INU, 380-500 V AC / 465-800 V DC, 416 A
EMC category: C4 category
Control Panel 2.8 OPX20
Standard I/O: I/O and Relay Option OC7C1
Modbus TCP OS7MT
Functional Safety: None, not upgradable
Other options according to model code
iC7 series air-cooled and liquid-cooled system modules are designed for fast integration, and powerful shaft and grid performance. They are amongst the most compact drives available on th...
Gross weight | 107 Kilogram | ||
Net weight | 73 Kilogram | ||
EAN | 5715253728070 |
Product series | +DAMA | iC7-Marine | |
Product group | IC7-60 | iC7-60 | |
Product category | SL | System module, liquid-cooled | |
Product type | IN | Inverter module, INU | |
Mains voltage | B5 | 380-500 V AC / 465-800 V DC | |
Current rating | -416A | 416 A | |
Power rating | 250 | 250 kW/350 HP | |
Protection rating | E00 | IP00/Open Type | |
EMC category | F4 | C4 category | |
Integration unit | +AE10 | Standard, no filter | |
Mains input device | +AJXX | None | |
DC fuses and devices | +AKFX | DC bus fuses | |
Cooling circuit connector type | +ANN1 | Push-in connection | |
Cooling circuit hose length | +AO20 | 2.0 m (6 ft) | |
Marine construction | +AFXX | None | |
Extra environmental protection | +AGCX | Coated boards | |
Communication interface, X1/X2 | +BAMT | Modbus TCP OS7MT | |
Communication interface, X0 | +BBEL | Ethernet port, no protocol | |
Standard I/O | +BDC1 | I/O and Relay Option OC7C1 | |
Functional safety | +BEXX | None, not upgradable | |
Control panel | +BF20 | Control Panel 2.8 OPX20 | |
Control panel mounting type | +BGK1 | Flush mount | |
Control panel cable length | +BH25 | 2.5 m (8 ft) | |
Control unit cable length | +BK15 | 1.5 m (5 ft), Fiber | |
StarCoupler board cable length | +BLXX | None | |
Option slot A | +CAM0 | Encoder/Resolver Option OC7M0 | |
Option slot B | +CBT0 | Temperature Measurement OC7T0 | |
Option slot C | +CCC1 | I/O and Relay Option OC7C1 | |
Option slot D | +CDX0 | None | |
Option slot E | +CEX0 | None | |
Option slot F | +CFX0 | None | |
Option slot G | +CGXX | None, without mounting plate | |
Option slot H | +CHXX | None, without mounting plate | |
Option slot I | +CIXX | None, without mounting plate | |
Option slot J | +CJXX | None, without mounting plate | |
Language package | +EL01 | Global | |
Customer specific application | +DBXX | None | |
Additional drive features 1 | +DD1X | None | |
Additional drive features 2 | +DE2X | None | |
Additional drive features 3 | +DF3X | None | |
Additional drive features 4 | +DG4X | None | |
Additional drive features 5 | +DH5X | None | |
High speed enabled | +DI6X | No | |
Customization file package ID | +EAXXXXXX | No customization | |
Product software ID | +ECXXX | Latest released version | |
Technical documentation | +EGIN | Installation guide | |
Documentation language | +EHEN | English | |
Customer-specific label | +EJXX | None | |
Shipping package | +TACB | Cardboard box package | |
Product specific marine cert. | +VBDN | DNV | |
Frame designation | IR10L | IR10L | |
Modelcode01 | IC7-60SLINB5-416AE00F4 | ||
Modelcode02 | +AE10+AKFX+ANN1 | ||
Modelcode03 | +AO20+BAMT+BDC1+BEXX+BF20 | ||
Modelcode04 | +BGK1+BH25+BK15+CAM0+CBT0 | ||
Modelcode05 | +CCC1+CDX0+CEX0+CFX0 | ||
Modelcode06 | +DAMA | ||
Modelcode08 | +EGIN+EHEN | ||
Modelcode09 | +VBDN | ||
Main unit Width | 140MM/5.5IN | 140MM/5.5IN | |
Main unit Height | 1295MM/51IN | 1295MM/51IN | |
Main unit Depth | 566MM/22.3IN | 566MM/22.3IN | |
Calculated Gross Weight [kg] | 107 | ||
Calculated Net Weight [kg] | 73 | ||
ECCN EU | Y901 | Y901 | |
ECCN US | 3A999.a | 3A999.a | |
AC voltage | 3X0-400/460/500VAC | 3X0-400/460/500VAC | |
check if complete | OK | OK | |
Continous current IH (1/5min) | 312A(500VAC) | 312A(500VAC) | |
Continous current IL (1/5min) | 416A(500VAC) | 416A(500VAC) | |
Cooling type | Liquid Cooled | Liquid Cooled | |
DC Bus current | 440A(675VDC) | 440A(675VDC) | |
DC Bus voltage | 465-800VDC | 465-800VDC | |
DC power | 297KW(675VDC) | 297KW(675VDC) | |
Enclosure rating | IP00 / OPEN TYPE | IP00 / OPEN TYPE | |
Help Counter | 1 | ||
Liquid temp. High Overload | 45°C/113°F | 45°C/113°F | |
Liquid temp. Low Overload | 45°C/113°F | 45°C/113°F | |
Liquid temp. Nominal load | 45°C/113°F | 45°C/113°F | |
Nominal AC current | 425A(500VAC) | 425A(500VAC) | |
Output frequency | 0-599Hz | 0-599Hz | |
Overload current IH (1/5min) | 360A(500VAC) | 360A(500VAC) | |
Overload current IL (1/5min) | 458A(500V) | 458A(500V) | |
Product Catalog | NO_VIEW | NO VIEW | |
Product Category -DrivesSymbol | System module, liquid-cooled | System module, liquid-cooled | |
Product Type - DrivesSymbol | Inverter module | Inverter module | |
Product View (Switch) | GLBL | Global (Standard) | |
Salescode part 1 | IC7-60SLINB5-416AE00F4 | IC7-60SLINB5-416AE00F4 | |
Salescode part 2 | +AE10+AKFX+ANN1 | +AE10+AKFX+ANN1 | |
Salescode part 3 | +AO20+BAMT+BDC1+BEXX+BF20 | +AO20+BAMT+BDC1+BEXX+BF20 | |
Salescode part 4 | +BGK1+BH25+BK15+CAM0+CBT0 | +BGK1+BH25+BK15+CAM0+CBT0 | |
Salescode part 5 | +CCC1+CDX0+CEX0+CFX0 | +CCC1+CDX0+CEX0+CFX0 | |
Salescode part 6 | +DAMA | +DAMA | |
Salescode part 7 | +EGIN+EHEN | +EGIN+EHEN | |
Salescode part 8 | +VBDN | +VBDN | |
Short circuit current rating | 100kA | 100kA | |
Start current Imax (3sec) | 624A | 624A | |
Storage temperature | -40...70°C/-40...158°F | -40...70°C/-40...158°F | |
Typecode Part 1 | 7SM-MASLINB5-416AE00F4 | ||
Typecode Part 2 | -000145522 | ||
Typical motor power PH2 (150%) | 200KW(500VAC) | 200KW(500VAC) | |
Typical motor power PL (110%) | 270KW(500VAC) | 270KW(500VAC) | |
Vendor | ERR01 | Cannot Determine Vendor |