Description
Extends the Safe Torque Off feature of VLT® drives with additional safety functions: Safe Stop 1 (SS1), Safely Limited Speed(SLS), Safe Maximum Speed (SMS) and Safe Speed Monitor (SSM).
Product details
| Gross weight | 13.6 kg | ||
| Net weight | 13.3 kg | ||
| Volume | 59.024 l | ||
| EAN | 5702427421882 |
Allocate codes for sales
| \\Customer Specific\\ | No |
Sales restriction control
| Matr grp for sales restriction | 0001 |
VLT® AQUA DRIVE FC 200 SERIES
| Product Group | (FC-) VLT® AQUA Drive FC- | ||
| Series | 202 | ||
| Power Rating | (P3K0) 3.0 KW / 4.0 HP | ||
| Phase | (T) Three phase | ||
| Mains Voltage | (4) 380 - 480 VAC | ||
| Enclosure | (P55) IP55 / Type12 Backplate | ||
| RFI Filter | (H3) RFI Class A1/B (C1) | ||
| Brake - Safe Stop | (X) No brake chopper | ||
| LCP | (G) Graphical Loc. Cont. Panel | ||
| Coating PCB | (X) Not coated PCB | ||
| Mains Option | (X) No Mains Option | ||
| Adaptation A | (X) Standard Cable Entries | ||
| Adaptation B | (X) No adaptation | ||
| A Option | (AX) No A Option | ||
| Software Release | (SXXX) Latest release std. SW. | ||
| B Option | (BX) No B Option | ||
| Software Language Pack | (X) Standard Language Pack | ||
| C0 Option MCO | (CX) No C0 option | ||
| C1 Option | (X) No C1 option | ||
| C Option Software | (XX) No software option | ||
| D Option | (DX) No D option | ||
| Frame Size | A5 | ||
| Typecode Part 1 | FC-202P3K0T4P55H3XGX | ||
| Typecode Part 2 | XXXSXXXXAXBXCXXXXDX | ||
| Calculated Gross Weight | 14.5 | ||
| Calculated Net Weight [kg] | 14.2 | ||
| Cross-Plant Configurable Mater | 200_SER | ||
| Division | 09 | ||
| Material Gross Weight | 13.6 | ||
| Material Net Weight | 13.3 | ||
| Modelcode01 | FC-202P3K0T4P55H3XGX | ||
| Modelcode02 | XXXSXXXXAXBXCXXXXDX | ||
| Product Catalog | NO VIEW | ||
| Product Group | A97 | ||
| Product Hierarchy | 09A9760360525 | ||
| Product View (Switch) | Global (Standard) | ||
| Recommended Factory | Cannot Determine Vendor | ||
| Vendor | Cannot Determine Vendor |
Product details
| Gross weight | 13.6 kg | ||
| Net weight | 13.3 kg | ||
| Volume | 59.024 l | ||
| EAN | 5702427421882 |
Allocate codes for sales
| \\Customer Specific\\ | No |
Sales restriction control
| Matr grp for sales restriction | 0001 |
VLT® AQUA DRIVE FC 200 SERIES
| Product Group | (FC-) VLT® AQUA Drive FC- | ||
| Series | 202 | ||
| Power Rating | (P3K0) 3.0 KW / 4.0 HP | ||
| Phase | (T) Three phase | ||
| Mains Voltage | (4) 380 - 480 VAC | ||
| Enclosure | (P55) IP55 / Type12 Backplate | ||
| RFI Filter | (H3) RFI Class A1/B (C1) | ||
| Brake - Safe Stop | (X) No brake chopper | ||
| LCP | (G) Graphical Loc. Cont. Panel | ||
| Coating PCB | (X) Not coated PCB | ||
| Mains Option | (X) No Mains Option | ||
| Adaptation A | (X) Standard Cable Entries | ||
| Adaptation B | (X) No adaptation | ||
| A Option | (AX) No A Option | ||
| Software Release | (SXXX) Latest release std. SW. | ||
| B Option | (BX) No B Option | ||
| Software Language Pack | (X) Standard Language Pack | ||
| C0 Option MCO | (CX) No C0 option | ||
| C1 Option | (X) No C1 option | ||
| C Option Software | (XX) No software option | ||
| D Option | (DX) No D option | ||
| Frame Size | A5 | ||
| Typecode Part 1 | FC-202P3K0T4P55H3XGX | ||
| Typecode Part 2 | XXXSXXXXAXBXCXXXXDX | ||
| Calculated Gross Weight | 14.5 | ||
| Calculated Net Weight [kg] | 14.2 | ||
| Cross-Plant Configurable Mater | 200_SER | ||
| Division | 09 | ||
| Material Gross Weight | 13.6 | ||
| Material Net Weight | 13.3 | ||
| Modelcode01 | FC-202P3K0T4P55H3XGX | ||
| Modelcode02 | XXXSXXXXAXBXCXXXXDX | ||
| Product Catalog | NO VIEW | ||
| Product Group | A97 | ||
| Product Hierarchy | 09A9760360525 | ||
| Product View (Switch) | Global (Standard) | ||
| Recommended Factory | Cannot Determine Vendor | ||
| Vendor | Cannot Determine Vendor |
