Frequency Converter
FC-102N400T7E5MH2TLC3XXSXXXXAXBXCXXXXDX
VLT® HVAC Drive FC-102
(N400) 400 KW / 550 HP, Specific Ratings: 315kW@525-550V, 400HP@575V, 400kW@690V
Three phase, 525 - 690 VAC *,IP54/Type 12+main shield
RFI Filter
Safe Stop
Graphical LCP + USB
Coated PCB, Mains Disconnect + Fuse
Latest release std. SW.
Frame: D7H
No A Option, No B Option
No C1 option, No D option
Other options according to Model Code
Danfoss VLT® HVAC Drive FC-102 Drive is dedicated toventilation, heating, and refrigeration applications. With a wide rangeof powerful standard and optional features, the Drive provides th...
| Gross weight | 200.3 Kilogram | ||
| Net weight | 200 Kilogram | ||
| EAN | 5715253047317 |
| Product View (Switch) | GLBL | Global (Standard) | |
| Product Group | FC- | VLT® HVAC Drive FC- | |
| Series | 102 | 102 | |
| Power Rating | N400 | (N400) 400 KW / 550 HP | |
| Phase | T | Three phase | |
| Mains Voltage | 7 | 525 - 690 VAC * | |
| Possible rating issue | WARN01 | Possible Rating Issue: | |
| Enclosure | E5M | IP54/Type 12+main shield | |
| RFI Filter | H2 | RFI Filter | |
| Brake - Safe Stop | T | Safe Stop | |
| LCP | L | Graphical LCP + USB | |
| Coating PCB | C | Coated PCB | |
| Mains Option | 3 | Mains Disconnect + Fuse | |
| Adaptation A | X | Standard Cable Entries | |
| Adaptation B | X | No adaptation | |
| Software Release | SXXX | Latest release std. SW. | |
| Software Language Pack | X | Standard Language Pack | |
| A Option | AX | No A Option | |
| B Option | BX | No B Option | |
| C0 Option MCO | CX | No C0 option | |
| C1 Option | X | No C1 option | |
| C Option Software | XX | No software option | |
| D Option | DX | No D option | |
| Frame Size | D7H | D7H | |
| Product Catalog | NO_VIEW | NO VIEW | |
| Typecode Part 2 | 3XXSXXXXAXBXCXXXXDX | ||
| Power 110% (NO) [KW] | 400 | 400 | |
| Height [mm] | 1978,0 | 1978,0 | |
| Width w/ no C options [mm] | 420,0 | 420,0 | |
| Depth [mm] | 386,0 | 386,0 | |
| Depth with Option A/B [mm] | 386,0 | 386,0 | |
| kVA | 478 | 478 | |
| Power Loss NO [W] | 5023 | 5023 | |
| Power Loss NO [W] | 5150 | 5150 | |
| Continuous Current (NO) [A] | 418 | 418 | |
| Intermittent Current (NO) [A] | 460 | 460 | |
| Continuous Current (NO) [A] | 400 | 400 | |
| Intermittent Current (NO) [A] | 440 | 440 | |
| Power Rating at 525-550V | 315kW | 315kW | |
| Power Rating at 575V | 400HP | 400HP | |
| Power Rating at 690V | 400kW | 400kW | |
| Calculated Gross Weight [kg] | 200.3 | ||
| Calculated Net Weight [kg] | 200 | ||
| ECCN EU | Y901 | Y901 | |
| ECCN US | 3A999.a | 3A999.a | |
| Vendor | ERR01 | Cannot Determine Vendor | |
| Recommended Factory | ERR01 | Cannot Determine Vendor | |
| Modelcode01 | FC-102N400T7E5MH2TLC | ||
| Modelcode02 | 3XXSXXXXAXBXCXXXXDX | ||
| Recommended Plant | ERR01 | ERR01 |