Frequency converter
FC-202N250T4E5MH4TLCVXXSXXXXAXB2CXXXXD0
VLT® AQUA Drive FC-202
(N250) 250 KW / 350 HP,
Three phase, 380 - 480 VAC,IP54/Type 12+main shield
RFI class A1 (C2)
Safe Stop
Graphical LCP + USB
Coated PCB, Multiwire cab+BBs+CMC+Fuse
Latest release std. SW.
Frame: D7H
No A Option, MCB-112 PTC Therm. Card
No C1 option, MCB-107 24V DC backup
ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Other options according to Model code
Danfoss VLT® AQUA Drive is dedicated to water and wastewaterapplications. With a wide range of powerful standard and optionalfeatures, the VLT® AQUA Drive provides the lowest overall cost of...
| Gross weight | 200.3 Kilogram | ||
| Net weight | 200 Kilogram | ||
| EAN | 5715253150536 |
| Product View (Switch) | GLBL | Global (Standard) | |
| Product Group | FC- | VLT® AQUA Drive FC- | |
| Series | 202 | 202 | |
| Power Rating | N250 | (N250) 250 KW / 350 HP | |
| Phase | T | Three phase | |
| Mains Voltage | 4 | 380 - 480 VAC | |
| Enclosure | E5M | IP54/Type 12+main shield | |
| RFI Filter | H4 | RFI class A1 (C2) | |
| Brake - Safe Stop | T | Safe Stop | |
| LCP | L | Graphical LCP + USB | |
| Coating PCB | C | Coated PCB | |
| Mains Option | V | Multiwire cab+BBs+CMC+Fuse | |
| Adaptation A | X | Standard Cable Entries | |
| Adaptation B | X | No adaptation | |
| Software Release | SXXX | Latest release std. SW. | |
| Software Language Pack | X | Standard Language Pack | |
| A Option | AX | No A Option | |
| B Option | B2 | MCB-112 PTC Therm. Card | |
| C0 Option MCO | CX | No C0 option | |
| C1 Option | X | No C1 option | |
| C Option Software | XX | No software option | |
| D Option | D0 | MCB-107 24V DC backup | |
| Frame Size | D7H | D7H | |
| Typecode Part 2 | VXXSXXXXAXB2CXXXXD0 | ||
| Product Catalog | GLBL | Global (Standard) | |
| Power 150% (HO) [KW] | 200 | 200 | |
| Power 110% (NO) [KW] | 250 | 250 | |
| Height [mm] | 1978,0 | 1978,0 | |
| Width w/ no C options [mm] | 420,0 | 420,0 | |
| Depth [mm] | 386,0 | 386,0 | |
| Depth with Option A/B [mm] | 386,0 | 386,0 | |
| kVA | 333 | 333 | |
| Power Loss NO [W] | 5137 | 5137 | |
| Power Loss NO [W] | 4566 | 4566 | |
| Power Loss HO [W] | 4039 | 4039 | |
| Power Loss HO [W] | 3575 | 3575 | |
| Continuous Current (NO) [A] | 480 | 480 | |
| Intermittent Current (NO) [A] | 528 | 528 | |
| Continuous Current (NO) [A] | 443 | 443 | |
| Intermittent Current (NO) [A] | 487 | 487 | |
| Continuous Current (HO) [A] | 395 | 395 | |
| Intermittent Current (HO) [A] | 592 | 592 | |
| Continuous Current (HO) [A] | 361 | 361 | |
| Intermittent Current (HO) [A] | 542 | 542 | |
| ATEX Marking 1 | ATEX: II (2) G [Ex eb Gb] [Ex | ATEX: II (2) G [Ex eb Gb] [Ex | |
| ATEX Marking 2 | db Gb] / II (2) D [Ex tb Db] | db Gb] / II (2) D [Ex tb Db] | |
| Calculated Gross Weight [kg] | 0.2 | ||
| Calculated Net Weight [kg] | 0.2 | ||
| ECCN EU | Y901 | Y901 | |
| ECCN US | 3A999.a | 3A999.a | |
| Plant from Orderline | F605 | F605 | |
| Vendor | ERR01 | Cannot Determine Vendor | |
| Recommended Factory | ERR01 | Cannot Determine Vendor | |
| Modelcode01 | FC-202N250T4E5MH4TLC | ||
| Modelcode02 | VXXSXXXXAXB2CXXXXD0 |