Frequency converter
FC-202P900T7E21H2XGC7XXLX1XXAQBPCXXXXD1
NB: F-frame platform available until December 31, 2025
VLT® AQUA Drive FC-202
(P900) 900 KW / 1250 HP, Specific Ratings: 750kW@525-550V, 1050HP@575V, 900kW@690V
Three phase, 525 - 690 VAC *,IP21 / Type 1
RFI Filter
No brake chopper
Graphical Loc. Cont. Panel
Coated PCB, Fuse
Condition Based Monitoring CBM
Frame: F1
Modbus TCP MCA 122, MCB-105 Relay Card
No C1 option, MCB-117 Real time clock option
Other options according to Model code
Danfoss VLT® AQUA Drive is dedicated to water and wastewaterapplications. With a wide range of powerful standard and optionalfeatures, the VLT® AQUA Drive provides the lowest overall cost of...
Gross weight | 1017.3 Kilogram | ||
Net weight | 1017 Kilogram | ||
EAN | 5715253731575 |
Product View (Switch) | GLBL | Global (Standard) | |
Product Group | FC- | VLT® AQUA Drive FC- | |
Series | 202 | 202 | |
Power Rating | P900 | (P900) 900 KW / 1250 HP | |
Phase | T | Three phase | |
Mains Voltage | 7 | 525 - 690 VAC * | |
Possible rating issue | WARN01 | Possible Rating Issue: | |
Enclosure | E21 | IP21 / Type 1 | |
RFI Filter | H2 | RFI Filter | |
Brake - Safe Stop | X | No brake chopper | |
LCP | G | Graphical Loc. Cont. Panel | |
Coating PCB | C | Coated PCB | |
Mains Option | 7 | Fuse | |
Adaptation A | X | Standard Cable Entries | |
Adaptation B | X | No adaptation | |
Software Release | LX1X | Condition Based Monitoring CBM | |
Software Language Pack | X | Standard Language Pack | |
A Option | AQ | Modbus TCP MCA 122 | |
B Option | BP | MCB-105 Relay Card | |
C0 Option MCO | CX | No C0 option | |
C1 Option | X | No C1 option | |
C Option Software | XX | No software option | |
D Option | D1 | MCB-117 Real time clock option | |
Frame Size | F1 | F1 | |
Typecode Part 2 | 7XXLX1XXAQBPCXXXXD1 | ||
Product Catalog | NO_VIEW | NO VIEW | |
Height [mm] | 2204,0 | 2204,0 | |
Width w/ no C options [mm] | 1400,0 | 1400,0 | |
Depth [mm] | 606,0 | 606,0 | |
Depth with Option A/B [mm] | 606,0 | 606,0 | |
Power Loss NO [W] | 12316 | 12316 | |
Power Loss NO [W] | 12798 | 12798 | |
Power Loss HO [W] | 10860 | 10860 | |
Power Loss HO [W] | 11291 | 11291 | |
Power Rating at 525-550V | 750kW | 750kW | |
Power Rating at 575V | 1050HP | 1050HP | |
Power Rating at 690V | 900kW | 900kW | |
Calculated Gross Weight [kg] | 0.41 | ||
Calculated Net Weight [kg] | 0.41 | ||
ECCN EU | Y901 | Y901 | |
ECCN US | 3A999.a | 3A999.a | |
Plant from Orderline | B901 | B901 | |
Vendor | ERR01 | Cannot Determine Vendor | |
Recommended Factory | ERR01 | Cannot Determine Vendor | |
Modelcode01 | FC-202P900T7E21H2XGC | ||
Modelcode02 | 7XXLX1XXAQBPCXXXXD1 |