Zoom the image with the mouse

FC-302N500T7E2MH2XLC7XXLX1XXA0B2CXXXXD0

Write a Review
SKU:
137G8526

Frequency converterFC-302N500T7E2MH2XLC7XXLX1XXA0B2CXXXXD0 VLT® AutomationDrive FC-302(N500) 500 KW / 650 HP, Specific Ratings: 400kW@525-550V, 500HP@…

Ask for a Quotation

Ask for a Quotation

Feel free to inquire
  • Security Image 1
Description

Frequency converter
FC-302N500T7E2MH2XLC7XXLX1XXA0B2CXXXXD0

VLT® AutomationDrive FC-302
(N500) 500 KW / 650 HP, Specific Ratings: 400kW@525-550V, 500HP@575V, 500kW@690V
Three phase, 525 - 690 VAC *,IP21/Type 1+mains shield
RFI Filter
No brake chopper
Graphical LCP + USB
Coated PCB, Fuse
Condition Based Monitoring CBM
Frame: E1H
PROFIBUS DP MCA 101, MCB-112 PTC Therm. Card
No C1 option, MCB-107 24V DC backup
ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db]
Other options according to Model code

Model code: FC-302N500T7E2MH2XLC7XXLX1XXA0B2CXXXXD0

The VLT® AutomationDrive represents a single drive concept that controlsthe entire range of operations from ordinary to servo like applicationson any machine or production line.

Gross weight 295.3 Kilogram
Net weight 295 Kilogram
EAN 5715253348759

 

Product View (Switch) GLBL Global (Standard)
Product Group FC- VLT® AutomationDrive FC-
Series 302 302
Power Rating N500 (N500) 500 KW / 650 HP
Phase T Three phase
Mains Voltage 7 525 - 690 VAC *
Possible rating issue WARN01 Possible Rating Issue:
Enclosure E2M IP21/Type 1+mains shield
RFI Filter H2 RFI Filter
Brake - Safe Stop X No brake chopper
LCP L Graphical LCP + USB
Coating PCB C Coated PCB
Mains Option 7 Fuse
Adaptation A X Standard Cable Entries
Adaptation B X No adaptation
Software Release LX1X Condition Based Monitoring CBM
Software Language Pack X Standard Language Pack
A Option A0 PROFIBUS DP MCA 101
B Option B2 MCB-112 PTC Therm. Card
C0 Option MCO CX No C0 option
C1 Option X No C1 option
C Option Software XX No software option
D Option D0 MCB-107 24V DC backup
Frame Size E1H E1H
Typecode Part 2 7XXLX1XXA0B2CXXXXD0
Product Catalog NO_VIEW NO VIEW
Power 150% (HO) [KW] 500 500
Power 110% (NO) [KW] 560 560
Height [mm] 2000,0 2000,0
Width w/ no C options [mm] 600,0 600,0
Depth [mm] 510,0 510,0
Depth with Option A/B [mm] 510,0 510,0
kVA 598 598
Power Loss NO [W] 8076 8076
Power Loss NO [W] 7852 7852
Power Loss HO [W] 6833 6833
Power Loss HO [W] 6678 6678
Continuous Current (NO) [A] 596 596
Intermittent Current (NO) [A] 656 656
Continuous Current (NO) [A] 570 570
Intermittent Current (NO) [A] 627 627
Continuous Current (HO) [A] 523 523
Intermittent Current (HO) [A] 784 784
Continuous Current (HO) [A] 500 500
Intermittent Current (HO) [A] 750 750
ATEX Marking 1 ATEX: II (2) G [Ex eb Gb] [Ex ATEX: II (2) G [Ex eb Gb] [Ex
ATEX Marking 2 db Gb] / II (2) D [Ex tb Db] db Gb] / II (2) D [Ex tb Db]
Power Rating at 525-550V 400kW 400kW
Power Rating at 575V 500HP 500HP
Power Rating at 690V 500kW 500kW
Calculated Gross Weight [kg] 295.3
Calculated Net Weight [kg] 295
ECCN EU Y901 Y901
ECCN US 3A999.a 3A999.a
Plant from Orderline B901 B901
Vendor ERR01 Cannot Determine Vendor
Recommended Factory ERR01 Cannot Determine Vendor
Modelcode01 FC-302N500T7E2MH2XLC
Modelcode02 7XXLX1XXA0B2CXXXXD0
Bottom Banner