Description
Frequency converter
VACON0100-3L-0144-7+IP54
VACON 100 Industrial
525-690 Vac 144 AmpIP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
E Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 09
Other options according to Model code
Model code:
VACON0100-3L-0144-7+IP54
VACON® 100 AC drives are ideal for saving energy, optimizing processcontrol and improving productivity. They are designed for multi-purposeuse while remaining easy to install, easy to com...
Gross weight | 109 Kilogram | ||
Net weight | 108 Kilogram | ||
EAN | 5714853316342 |
Product View (Switch) | GLBL | Global (Standard) | |
Segment | NONE | VACON 100 Industrial | |
Region Code | -R00 | R00 International | |
Mains voltage | -7 | 525-690 Vac | |
Current rating | -0144 | 144 Amp | |
Installation options | -DM | DM Drive Module | |
Enclosure | +IP54 | IP54/NEMA12 | |
Control panel | +HMGR | Graphical Keypad MK01 | |
EMC emission limit category | +EMC3 | C3 Commercial&Industry Environ | |
Common mode filter (for DM) | +P000 | No Option | |
DUT filter (for DM) | +P000 | No Option | |
Brake chopper | +DBNO | No dynamic braking device | |
Real time clock option | +SRNO | No Battery for real time clock | |
Configurable power range | NONE | None | |
Power connections | +P000 | No Power options (+P000) | |
Cable entry | +QGLM | Metric conduit plate | |
Additional Equipment B | +Q000 | No option for Qxxx_B (+Q000) | |
Additonal Equipment C | +Q000 | No additonal option for Qxxx_C | |
Shipping package | +GSCB | Cardboard Box as Shipping pack | |
Marine construction | +E000 | no option | |
B-Slot Option Board | +SBF3 | F3,3 Relay board | |
C- Slot Option Board | +SC00 | No board | |
D-Slot Option Board | +SD00 | No board | |
E-Slot Option Board | +SE00 | No board | |
Internal FB selection | +FBM1 | Std protocol,Modbus,N2,BacNet | |
Documentation level | +DQCK | Quick Guide | |
Document language preference | +DLUK | English | |
Firmware Language Pack | +FL01 | UK, DE, FI, SE, IT, FR lang | |
Application | +A0000 | No Application | |
Parameter Set | +L0000 | No application parameter set | |
Motor parameter default freq | +LS50 | 50 Hz def motor freq settings | |
Unit for measure for display | +LSSI | Metric Units of Measure | |
Labeling options | +LPC1 | no additional labels | |
UL approval | +GAUL | UL Approval (+GAUL) | |
Marine approval | NONE | None | |
RCM Approval | +GACT | RCM Approval N16307 | |
KC approval | +GAKC | KC Approval | |
Ukrainian approval | +GAUA | Ukrainian Approval | |
EAC Approval | +GAEA | EAC Approval | |
Auxilary power supply | +C000 | no option | |
DC power supply for aux device | +C000 | no option | |
AC socket for aux devices | +C000 | no option | |
Input Devices | NONE | none_ | |
Common mode filter (for ED) | +P000 | no option | |
DU/DT, Sine filter (for ED) | +P000 | no option | |
Terminal Options | NONE | none_ | |
Door Equipments | +C000 | no option | |
Cabinet heater | +C000 | no option | |
Cabinet light | +C000 | no option | |
Motor heater control | +C000 | no option | |
Emergency stop options | +C000 | no option | |
Insulation fault sensor | +C000 | no option | |
Cabling from top | +C000 | no option | |
Back channel cooling | +C000 | no option | |
Cabinet Plinth | +C000 | no option | |
Empty extension segment | NONE | None | |
Standardized cabinet solution | NONE | None | |
Engineered cabinet solution | NONE | None | |
Product Group | VACON | VACON | |
Product Series | 0100 | Vacon 100 series | |
Phase | -3L | 3 Phase AC Input | |
Customized | +BM26 | Vacon 100 | |
Main Circuit | +M000 | NONE | |
Firmware | +F0072 | Vacon0100 Software package | |
Max output frequency | NONE | None | |
Terminal Box | +T000 | NONE | |
Bypass Control Operation Mode | NONE | none_ | |
Bypass Input Type | NONE | none_ | |
Bypass power connection type | NONE | none_ | |
CE approval | +GACE | CE Approval (+GACE) | |
ATEX Approval | NONE | None | |
County Specific Approval | NONE | None | |
Warrenty time | +WT01 | Warranty 12/18 months (+WT01) | |
Frame Size | MR09 | Frame 09 | |
Product Catalog | NO_VIEW | NO VIEW | |
Modelcode01 | VACON0100-3L-0144-7 | ||
Modelcode02 | +IP54 | ||
Calculated Net Weight [kg] | 120 | ||
Calculated Gross Weight [kg] | 121 | ||
Motor Power Low Overload [kW] | 132 | 132 | |
Motor Power High Overload [kW] | 110 | 110 | |
Dimensions WxHxD [mm] net | 480 X 1150 X 365 | 480 X 1150 X 365 | |
Dimensions WxHxD [mm] Gross | 730 X 1310 X 570 | 730 X 1310 X 570 | |
Dimensions WxHxD [mm] | 480X1150X365 | 480X1150X365 | |
Continuous Current (NO) [A] | 144 | 144 | |
Continuous Current (HO) [A] | 125 | 125 | |
Motor Power HP Low Overload | 132 | 132 | |
Motor Power HP High Overload | 110 | 110 | |
Typecode Part 1 | 70-AB3L01447W09B530BM26 | ||
Typecode Part 2 | -00114875 | ||
Stockcode part 1 | 70-AB3L01447W09B530BM26 | ||
Stockcode part 2 | -00114875 | ||
check if complete | OK | OK | |
Plant from Orderline | C302 | C302 | |
Vendor | ERR01 | Cannot Determine Vendor | |
Recommended Factory | ERR01 | Cannot Determine Vendor | |
Help Counter | 5 | ||
Help Counter | 2 | ||
Calculated Net Weight | 108 | ||
Sub family identification | NONE | Normal customer ordered | |
ECCN US | 3A999.a | 3A999.a | |
ECCN EU | Y901 | Y901 |